State Industries SSE-5 Water Heater User Manual


 
9
MEDIUM TEMPERATURE - ONE HEATER VERTICAL STORAGE TANK
MEDIUM TEMPERATURE - ONE HEATER HORIZONTAL STORAGE TANK
*PIPE RELIEF VALVE TO OPEN DRAIN.
†TANK TEMPERATURE CONTROL SET AT DESIRED
TEMPERATURE - MAX. 170°F (76.6 mm). HEATER
THERMOSTAT SET AT LEAST 5° HIGHER.
INSTALL IN ACCORDANCE WITH ALL LOCAL
CODES.
CAUTION: IF BUILDING COLD WATER SUPPLY HAS
A BACK-FLOW PREVENTER, CHECK VALVE OR
WATER METER WITH CHECK VALVE, PROVISIONS
FOR THERMAL EXPANSION OF WATER IN THE HOT
WATER SYSTEM MUST BE PROVIDED.
DANGER:
TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE
TEMPERATURE AT FIXTURES. SEE WATER TEMPERATURE
CONTROL WARNING ON PAGES 17 & 18. IF HIGHER PREHEAT
TEMPERATURES ARE NECCESARY TO OBTAIN ADEQUATE
BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE FOR HOT WATER
SUPPLIED TO FIXTURES..