Stanley Black & Decker 2005 Series Door User Manual


 
canceLLIng user dIsabLe In management/empLoyee access mode
If you decide user code holders should no longer have the ability
to disable the lock, perform the following procedure.
5 6 master code #
♪♪
0 #
♪♪
0 #
♪♪
User code holders will no longer be able to disable the lock,
although the master code holder and supervisor code holder will
still have the ability to do so.
takIng the Lock out of management/empLoyee access mode
If you no longer want the lock to function in the management/
employee access mode, enter the following sequence.
3 2 master code or supervisor code #
♪♪
1 #
♪♪
1 #
♪♪
The lock will now operate on any valid code at any time.
managIng duress
turnIng duress on
If your lock was ordered with time duress capability and an optional
duress module is installed, the feature can be turned on as follows.
3 8 master code #
♪♪
1 #
♪♪
1 #
♪♪
turnIng duress off
The duress feature can be turned off as follows.
3 8 master code #
♪♪
0 #
♪♪
0 #
♪♪
verIfyIng duress
If duress is enabled, you can tell if the lock has sent a silent alarm.
Fifteen minutes or more after a duress signal has been sent, press
and hold down the button for at least four seconds. The lock will
emit a continuous alternating series of high and low pitch beeps
to indicate that a duress signal has been sent. Reset the duress
indication by entering the lock’s master code within one minute after
the verification signal ends.
managIng audIt traIL
capturIng an audIt traIL
Your lock must have been ordered with this option. Using the audit
trail feature also requires an optional keypad extension (S&G part
number 6101-201), as well as an audit trail software kit (S&G part
number 6103-100). The lock records the last 63 events, in the order
they occurred. After the 63rd event, the lock overwrites the oldest
event with the new one, so you always have access to the most recent
63 events. To download the audit trail through the optional keypad
extension, hold the Dallas iButton key provided in the audit trail kit to
the receptacle in the keypad extension, and enter the following.
2 8 master code #
The lock will beep three times when the download is complete.
You may then remove your iButton key from the keypad
extension’s receptacle. The information now stored in the key is
a copy of what is in the lock. The lock’s audit information is not
erased in the download process.
© Copyright 2006, Sargent & Greenleaf
Page 7
Operating instructiOns
S&G
®
Z
03
D-Drive
Multi-User Electronic Safe Lock