Stanley Black & Decker 2005 Series Door User Manual


 
deLetIng an exIstIng code
The holder of the master code (position 0) can delete any other code.
The master code cannot be deleted under any circumstances.
The holder of the supervisor code (position 1) can delete user
codes. The supervisor code cannot be used to delete the master
code or itself.
Here is the process for deleting a supervisor code.
7 4 master code #
♪♪
1 #
♪♪
#
♪♪
#
♪♪
To delete a user code in position 5, use the following sequence.
7 4 master code or supervisor code #
♪♪
5 #
♪♪
#
♪♪
#
♪♪
To delete a time delay override code, see the time delay section.
managIng tIme deLay
creatIng, changIng, deLetIng a tIme deLay
Time delay is a security feature that enforces a predetermined waiting
period between the entering of a valid lock code and the actual
opening of the lock. The delay period can be set from 1 to 99 minutes.
The opening window is a period of time immediately after the time
delay during which you can enter a valid lock code to open the lock.
The factory default opening window is 2 minutes, but it can be
changed to any value between 1 and 10 minutes.
Note: Changes to an existing time delay or opening window can only be
accomplished during the opening window period. This means you must enter
a valid operating code for the lock, wait for the time delay to expire, then
begin the appropriate programming sequence rather than opening the lock.
The programming sequence for setting, changing, or deleting a
time delay period is as follows. The period can be anywhere from
1 to 99 minutes.
7 4 master code #
♪♪
0 0 #
♪♪
length of desired time delay period #
♪♪
length of desired time delay period #
♪♪
To delete a time delay, enter 0 for the desired time delay length.
changIng the openIng WIndoW duratIon
The length of the opening window period is set as follows. The period
can be anywhere from 1 to 10 minutes.
7 4 master code #
♪♪
0 1 #
♪♪
length of desired opening window period #
♪♪
length of desired opening window period #
♪♪
managIng tIme deLay overrIde
This optional feature determines whether or not you can override the
time delay waiting period. There may be special circumstances that
make it desirable to open the lock before time delay expires, such as
during cash pickups by an armored car service. Time delay override
only works when the lock is being operated in time delay mode. Your
lock is capable of two different types of time delay override. Single
control time delay override allows the TDO code holder to simply enter
his code to open the lock. The delay period is completely bypassed.
The other type of time delay override is dual control TDO. To use this
type of time delay override, it is necessary to start the lock’s time
delay by entering any valid code other than the TDO code. Then, within
one minute, enter the TDO code. The lock will open immediately. This
type of time delay override places a secondary control on the TDO
code holder, adding a measure of extra security.
turnIng sIngLe controL tIme deLay overrIde on
If your lock was ordered with time delay override capability, single
control TDO can be turned on as follows.
4 6 master code #
♪♪
2 #
♪♪
2 #
♪♪
turnIng duaL controL tIme deLay overrIde on
If your lock was ordered with time delay override capability, dual
control TDO can be turned on as follows.
4 6 master code #
♪♪
1 #
♪♪
1 #
♪♪
turnIng tIme deLay overrIde off
4 6 master code #
♪♪
0 #
♪♪
0 #
♪♪
When time delay override is turned off, the time delay override
code is erased. PIN position #9 can now be used to store a
regular user code.
© Copyright 2006, Sargent & Greenleaf Page 5
Operating instructiOns
S&G
®
Z
03
D-Drive
Multi-User Electronic Safe Lock
2005 Series