SPX Cooling Technologies API 610 Heat Pump User Manual


 
CR/EN (1004) 4.0 Commissioning 25
CombiPro
4 Commissioning
4.1 Inspection of the pump
Check whether the pump shaft turns freely. Do this by turning the shaft end at the
coupling a few times by hand.
4.2 Inspection of the motor
Check whether the fuses have been mounted.
4.3 Pumps with oil-bath lubricated bearings
! Pumps provided with oil-bath lubricated bearings are shipped without oil and
must be filled with oil prior to commissioning the pump!
For the specification of the oil to be used, see paragraph 10.3 "Lubricants".
1 Remove the oil filler cap (2130).
2 Fill the bearing bracket through the oil filling orifice till the oil shows in the constant
level oiler.
3 Fit the oil filler cap.
4 Top up the constant level oiler entirely.
5 See the indication plate (see figure 6) for the right oil level.
Figure 6: Oil level indication.