SPT WA-1310E Air Conditioner User Manual


 
SAFETY POWER SUPPLY CORD:
This Portable Air Conditioner is provided with a Leakage Current Detection and
Interruption circuit (LCDI) built into the plug of the power supply cord.
This device provides protection to reduce the risk of fire due to arcing faults in the
power-supply cord. Each time before using the Portable Air Conditioner, follow the
“plug Testing Instructions” given below to ensure that the LCDI circuit is functioning
properly.
PLUG TESTING INSTRUCTIONS:
1. PRESS TEST BUTTON. UNIT SHOULD TRIP.
2. PRESS RESET BUTTON FOR USE.
Note: Please do not use this item if above test fails.
The conductors inside this power supply cord are surrounded by shields, which
monitor the leakage current. These shields are not grounded. Periodically examine
the cord for any damage. If the shield gets exposed, immediately unplug the power
supply cord and do not use the Portable Air Conditioner. Do not repair a damaged
cord. Replace the damaged cord with a new replacement power supply cord or
obtain a new replacement power supply cord by calling Sunpentown Int’l Inc. at
1-800-330-0388.
In the event the LCDI Plug of the power supply cord trips by itself, first examine the
cord for any damage. If there is no damage to the cord then press the RESET
button. If the LCDI Plug trips again, then immediately unplug the power supply
cord. Replace the damaged cord with a new replacement power supply cord or
obtain a new replacement power supply cord by calling Sunpentown Int’l Inc. at
1-800-330-0388.
Do not use the TEST and RESET buttons as an ON/OFF switch. They are only
meant to periodically check the LCDI plug.
19
05-03-457 A029-OK.PDF
Sales: 800-934-9194