Soleus Air KFR/KFS Series Air Conditioner User Manual


 
HOW TO INSTALL DRAIN ACCESSORIES
There will be some water dripping from the condenser when the heat pump is working during the heating mode.
Two drain caps, a drain elbow with rubber collar and a plastic hose (5/8” x 6”) are supplied for user’s choice.
INSTALLATION STEPS:
(1) Observe the drainage flow of the three drain holes on the base while pouring water into the condensing unit
evenly around the condenser. (Figure 1)
(2) Connect the drain elbow and the plastic hose. (Figure 2)
(3) Insert the drain elbow connected with the drain hose into the hole which has the largest drainage flow and
rotate it to the wall side of the building in order to make the drainage flow against the wall. The other two holes
of the base should be stopped by using the two drain caps. (Figure @)
NOTE:
If the drain hole inserted with the drain elbow is not at the desired location, adjust the level of the condensing unit
slightly, and then reinstall the accessories according to the above steps.
- 24 -