Sinclair ASH-13AK Air Conditioner User Manual


 
Turbo function
The turbo function is available in Cool and Heat modes.
Dry function
Dry function is available in Cool and Dehumidifying modes.
Auto fan speed control
In this mode, indoor fan can run with Hig, Mid, Low speeds.
Up and down swing control
Displayer
Running figure and mode figure display
After powered on, the figure will be displayed, then only Power/running indicator turn on. When using
remote conroller to open the unit, it will turn on, at the same time to display current setting running modes.
Dual 8 display
PG motor lock protection
When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order
to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on,
that dual 8 will display lock error code H6; If current is unit off, will not display the block error information.
After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet
vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop
at current position, inner fan motor is running, guide louver will resume to swing.From Cool, Dry, Fan modes
to Heat mode, the guide louver will be opened at D position, when turn on swing will run at (A-D); from Heat
mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-C).
When unit is turned off, the guide louver will turn to position 0, the swing is only available after preset the
swing function, and indoor unit is running.
Note: When to set up at position L to B, A to C, B to D, the guide louver will swing between position W to D.
Tpreset
Tpreset
Tpreset
1hr.
2hrs. 2hrs. above
Tpreset temp.
Power-off Memory
Memory contents: Mode, UP/DOWN Swing,
light,
Set temp, Set fan speed.
After de-energized, and re-energized, the unit will start to run with the memory function automatically.
The system, if the last
remote control signal do not set timer function, will memorize the
last remote control signal and run according to it. If the last
remote control signal has set timer function, the system is de-energized before the set time,when re-energized, the system
will memorize the timer function, the set time will recalculate. If the last remote control signal has set timer function and the
system is de-energized after the set time, when re-energized, the system will memorize the running status before de-energized.
When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 16-30 ).
When the preset temperature display signal has been received, the nixie tube will display the preset temperature;
If the display ambient temperature signal has been received, the nixie tube will display the current indoor ambient
temperature, if to set up others by remote controller that the display will maintain its status. At displaying ambient
temperature, the unit received the remote control signal, it will display 5s preset temperature then turn to ambient
temperature display. The ambient temperature sensor malfunction will display F1; Indoor tube sensor will display
F2, wire jumper cap protection displays C5.