(6) Turbo function
The turbo function is available in Cool and Heat modes.
(7) Dry function
Dry function is available in Cool and Dehumidifying modes.
(8) Auto fan speed control
In this mode, indoor fan can run with Hig, Mid, Low speeds.
(10) Displayer
Running figure and mode figure display
Dual 8 display
After powered on, the figure will be displayed, then only Power/running indicator turn on. When using
remote conroller to open the unit, it will turn on, at the same time to display current setting running modes.
When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 16-
30 ). Under Auto mode, cooling and fan will display 25 , heating will display 20 , cooling only control
display 25 .
(9) Up and down swing control
After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet
vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop
at current position, inner fan motor is running, guide louver will resume to swing.From Cool, Dry, Fan modes
to Heat mode, the guide louver will be opened at D position, when turn on swing will run at (A-D); from Heat
mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-C).
(11) PG motor lock protection
When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order
to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on,
that dual 8 will display lock error code H6; If current is unit off, will not display the block error information.
LCD Display
When cooling and dehumidifying, the Cool and indicator will turn on, when heating, the Heat and Run indicaor
will turn on, when in fan mode, the indicator will turn on.