Sinclair ASH-09AK Air Conditioner User Manual


 
Operating Procedures / Photos
Screw off the screw, then press the clasps in by
till they loose, then lift up wards the electric cover
and the light board.
4. Disassemble the electric box cover
5. Disassemble water tray
Electric box cover
6. Disassemble the electric box
Loosen the grounding wire of the evaporator, re-
move the temperature sensor for the pipe, put
out the connection lines for the indoor motor.
Screw off the screws fixing the electric box. Re-
move the electric box.
Grounding wire
Connector
Claslp
Water tray
Connector
Tube Sensor
Screw
Screw
Light Board
Loosen up the clasp at the front of and the rear of
water tray sub-assy and lift them up, can take out
the water tray sub-assy.
Note: Due to the water tray is connected with the
water drainage pipe, please pay more attention do
not to damage the fin on evaporator.