Operation / Repair Parts 4
OPERATION
Risk of electric shock. Before attempting to
check why a unit has stopped operating, disconnect the
battery from the unit. Do not handle a pump or pump
motor with wet hands or when standing on wet or damp
surface, or in water. Do not use this pump in marine
applications.
1. The shaft seal depends on water for lubrication. Do
not operate the pump unless it is pumping water. The
seal will be damaged if the pump is allowed to run
dry. Pump water only.
2. The pump motor must be connected to a fully
charged automotive, tractor or marine type battery of
the proper voltage, or a direct current, full wave recti-
fying 12 Volt power supply with a filter, to smooth
out any current surges.
3. Do not use a battery charger to power this pump.
BATTERY OPERATION
Fire or Explosion Hazard. Follow the bat-
tery manufacturer’s recommendations for the mainte-
nance and safe use of the battery. The battery can cause
a fire if the battery terminals are short circuited. Never
allow the DC terminals to touch each other. Take special
care NOT to touch the battery cable clamps together or
to drop a tool (wrench) across the terminals. This will
“short circuit” the battery.
• Keep sparks and flames away from the battery.
• Use the battery in a cool, dry, well ventilated area.
• Do not allow children to play around the battery.
Severe Burn Hazard. Battery acid is corro-
sive and can cause severe burns and blindness. Do not
spill on skin or clothing. Always wear eye, skin and hand
protection when working with the battery.
1
2
3
5
6
7
8
9
4
11
10
®
Key Part
No. Description Qty. P3010
1 Hose Adapter, 1-1/4” 1 007-022
2 Screws, Handle 2 670-646
3 Handle 1 383-147-B
4 Pump Cover* 1 230-375-B
5 Gasket, Volute 1 345-031
6Volute 1 847-002
7 Screws, Volute 9 670-784
8 Pump Screen 1 667-013
9 Screws, Screen 3 670-646
10 Replacement Fuse 1 344-001
11 Power Cord 1 992-697
REPAIR PARTS LIST