Dulcodes UV-Desinfektionsanlage
Page 49
ProMinent
®
Settings
NOTE
If a remainder occurs when the factor is processed, the S2Ca counts up the remainder
values. When the sum reaches or exceeds “1” the S2Ca will activate a stroke. This ensures
that the stroke number corresponds exactly to the factor throughout the dosing operation.
The number of input pulses which have not been processed are stored by the S2Ca in the
stroke memory. The stroke buffer is limited to the batch size when memory is not activated
(- with “Memory” at 65535 stokes). You can delete it by switching to a different operating
mode.
You can optimally adapt the S2Ca to the respective process, e.g. in connection with contact
water meters.
“Memory” extension function
The “memory” extension function can be optionally activated (“mem” appears in the LCD
display). When “Memory” is activated the S2Ca adds any strokes which could not be carried
out up to the maximum capacity of the stroke buffer – 65535 strokes. If this maximum capacity
is exceeded the pump will register a fault.
7.4.4 Settings for “batch” operating mode (BATCH menu)
In addition to those settings menus described in 7.5, there is an additional BATCH menu in the
overall SET menu for the “batch” operating mode.
P
P P
P
Continuous
display
Set
Set
Mem
Batch
Set
Mem
Batch
L
The “batch” operating mode is a variant of the “contact” operating mode (see 7.4.3).
You can pre-select a stroke number (no breaks, whole numbers only from 1 to 65535) as well
as a feed quantity (batch). To switch between entries for “stroke number” and “feed quantity”
press the i key 1x in the corresponding menu option (see also overview “operating/settings
diagram”, fold-out page).
The “batch” operating mode is intended for large dosing quantities.
Metering can be actuated by pressing the P-key or via a pulse from the “external control
socket”.
The number of input pulses which have not been processed are stored by the S2Ca in the
stroke memory. The stroke buffer is limited to the batch size when memory is not activated
(- with “Memory” at 65535 stokes). You can delete it by switching to a different operating
mode.
“Memory” extension function
The “memory” extension function can be optionally activated (“mem” appears in the LCD
display). When “Memory” is activated the S2Ca adds any strokes which could not be carried
out up to the maximum capacity of the stroke buffer – 65535 strokes. If this maximum capacity
is exceeded the pump will register a fault.