Shinco KFR-25GWZ BM Air Conditioner User Manual


 
Shinco Service Manual
- 48 -
When condenser temperature is higher than 60℃, the compressor will stop, and hen the condenser
temperature lower to 50℃ and keep for 5 minutes, and compressor frequency will rise to former value
4.4. Dehumidifying mode
4.4.1 Temperature set and motor control in dehumidifying mode
The compressor and outdoor fan run in dehumidifying mode similar as cooling mode,
and the temperature can be set.
The indoor motor speed need to be set in low speed.
4.4.2 Compressor frequency on dehumidifying mode
The maximum frequency in dehumidifying mode is F3,and the frequency changes as following
fig.
4.4.3 The louver control in dehumidifying mode
The Louver control in dehumidifying mode is same as cooling mode.
4.4.4 Protection
The Indoor heat exchanger anti-frozen and Outdoor heat exchanger anti-overheat is same as
cooling mode.
4.5. Heating mode
4.5.1 Compressor frequency controlling
a. Frequency control when starting
Temperature difference= Room temperature (RT)-Set temperature (ST)
RT-ST