Shinco Service Manual
- 45 -
2. Frequency table
F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
KFR-25GWZ/BM
COOLING
0 30 35 40 45 52 55 58 66 69 73
KFR-25GWZ/BM
HEATING
0 30 35 40 45 52 55 59 66 69 73
KFR-35GWZ/BM
COOLING
0 30 36 42 48 54 61 66 72 78 84
KFR-35GWZ/BM
HEATING
0 30 36 42 48 54 61 66 72 78 84
KFR-50GWZ/BM
COOLING
0 30 36 43 49 56 64 72 77 82 87
KFR-50GWZ/BM
HEATING
0 30 36 43 49 58 67 77 81 84 87
KFR-70GWZ/BM
COOLING
0 30 34 39 44 48 52 57 62 67 72
KFR-70GWZ/BM
HEATING
0 30 35 40 46 51 56 62 67 73 78
3. Method of Testing the System at a Fixed Frequency
Cooling
Capacity(MIDDLE
FREQUENCY)
Cooling rated capacity Heating Capacity(MIDDLE
FREQUENCY)
Heat rated capacity
1. Start the air conditioner
2.Operate remote controller as following
Mode : Cool mode
Set temp. : 18℃
indoor fan : high
Mode : Cool mode
Set temp. : 16℃
indoor fan : high
Mode : heat mode
Set temp. : 28℃
indoor fan : high
Mode : heat mode
Set temp. : 30℃
indoor fan : high
Press ‘powerful’ button 5 times with 10 seconds.