Shinco KFR-25GWZ BM Air Conditioner User Manual


 
Shinco Service Manual
- 16 -
7. Sensor Resistance Table
7.1 KFR-25GWZ/BMKFR-35GWZ/BM Sensor Resistance Table
7.1.1 indoor air sensor、indoor pipe sensor、outdoor air sensor、outdoor pipe sensor
R-T datasheet 10K±0.5% ;3976K±0.5%,B(25/85)=3976K±0.5% R-T datasheet
Temp.() R(KΩ) Temp.() R(KΩ) Temp.()R(KΩ) Temp.() R(KΩ)
-30
180.719
4
26.832
38
5.764
72
1.627
-29
169.891
5
25.522
39
5.534
73
1.573
-28
159.763
6
24.284
40
5.315
74
1.522
-27
150.289
7
23.113
41
5.105
75
1.472
-26
141.422
8
22.006
42
4.905
76
1.425
-25
133.124
9
20.958
43
4.713
77
1.379
-24
125.355
10
19.967
44
4.530
78
1.335
-23
118.079
11
19.028
45
4.355
79
1.293
-22
111.264
12
18.139
46
4.188
80
1.252
-21
104.879
13
17.297
47
4.028
81
1.213
-20
98.895
14
16.499
48
3.875
82
1.176
-19
93.284
15
15.742
49
3.728
83
1.140
-18
88.023
16
15.024
50
3.588
84
1.105
-17
83.089
17
14.344
51
3.454
85
1.072
-16
78.458
18
13.698
52
3.325
86
1.040
-15
74.112
19
13.085
53
3.202
87
1.009
-14
70.032
20
12.503
54
3.084
88
0.980
-13
66.200
21
11.950
55
2.971
89
0.951
-12
62.599
22
11.425
56
2.863
90
0.924
-11
59.216
23
10.926
57
2.760
91
0.897
-10
56.035
24
10.451
58
2.660
92
0.872
-9
53.044
25
10.000
59
2.565
93
0.848
-8
50.231
26
9.571
60
2.474
94
0.824
-7
47.583
27
9.162
61
2.386
95
0.802
-6
45.091
28
8.773
62
2.302
96
0.780
-5
42.744
29
8.403
63
2.221
97
0.760
-4
40.534
30
8.051
64
2.144
98
0.740
-3
38.451
31
7.715
65
2.070
99
0.720
-2
36.487
32
7.395
66
1.998
100
0.702
-1
34.636
33
7.090
67
1.930
101
0.684
0
32.890
34
6.799
68
1.864
102
0.667
1
31.242
35
6.522
69
1.801
103
0.651
2
29.687
36
6.257
70
1.741
104
0.635
3
28.219
37
6.005
71
1.683
105
0.620