Figure 19: Wire Spacers.
Figure 20: Wire Spacer in Place.
the structure.
5. Project a level line from the center point of the elbow. Using this center
point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole out
on both the interior and exterior wall surface.
Initial Installation
QUALIFIED INSTALLERS ONLY
FREESTANDING DIRECT VENT KIT WITH COUPLER:
KIT COMPONENTS:
Quantity Description Quantity Description
1 Horizontal direct vent termination cap 1 Wall Thimble
2 Flue collar adapters (only one used) 4 Wire spacers
4 T-20 Torx screws 3 Decorative rings
1 Ø6” (17 cm) 90° elbow 1 4 oz tube RTV silicone
1 Inside nish trim collar 20
9
/16” tech screws
1 5’ (190cm) length of Ø4” (10cm) double walled ex pipe 8 1” wood screws
2 24” (61cm) section of Ø6” (17cm) straight pipe 1 Vinyl siding deector
Please ensure that all components are supplied with this kit. If components are missing or have
been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if
components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1. Decide on a location for the unit that will meet any or all local code requirements. Refer “Planning
Your Installation” and “Clearances to Combustibles”.
2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing
pipes are in the way of the venting system as it passes through the wall. If obstructions are found in
the wall it may be necessary to adjust the location of the appliance.
3. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-
crimped end on the unit
4. Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit
16
6. Frame the hole as shown in Figure 25.
7. Install the wall thimble and secure the
thimble to the inner wall surface.
8. With the appliance still in place install
the 24” (61 cm) horizontal section on the
elbow and let this section of pipe protrude
through the exterior surface. Mark the pipe
so that when it is cut it will be ush with
the exterior wall.
9. Dismantle the outer pipe sections.
10. Remove the 4” (10 cm) ue collar from the
unit and remove any loose sealant. Install the new Ø 4” (10 cm) by 5” (12.5
cm) ue collar provided in this kit.