Shark S1209 Vacuum Cleaner User Manual


 
OPERATING INSTRUCTIONS
FAMILIARISEZ-VOUS AVEC VOTRE ASPIRATEUR SANS
SAC VERTICAL
Changing the Headlight Bulb
Warning:
To reduce the risk of
electric shock, the power cord
must be disconnected before removing
the dust cup, HEPA-Type filter,changing
the filters or performing
maintenance/trouble shooting checks.
5. Replace the new bulb by pushing
it in.
6. Replace the head light lens by pushing
it in so that it snaps back in place.
Notches
Fig. 26
1. Turn unit “Off” and unplug from wall
outlet.
2. With a flat head screw driver, snap
off the lens cover by pressing down
on the two notches on the lens
cover. (Fig. 26)
3. Lift off the head light lens.
4. Remove the light bulb by pulling it
out carefully.
PROBLEM SOLVING
This appliance was inspected thoroughly and was in good operating condition when it
was shipped from the factory. If a minor problem occurs, it usually can be solved quite
easily when the cause is found. T herefore, this checklist is provided for your
convenience.
PROBLEM POSSIBLE CAUSE POSSIBLE
Cleaner Won’t
Run
1. Not properly plugged into
wall outlet.
2. No electricity in wall outlet.
3. On/Off switch not turned on.
4. Motor thermostat tripped.
5. Blown fuse/tripped breaker.
1. Plug in firmly.
2. Check fuse or breaker.
3. Push on/off switch to on
4. Reset motor thermostat. (page 7 )
5. Reset circuit breaker or replace fuse.
Cleaner Won't
Pick Up
1. Full or clogged dust cup.
2. Wrong pile height setting.
3. Clogged nozzle.
4. Clogged dust inlet port.
5. Clogged hose.
6. Broken belt.
7. Hose not inserted fully.
8. Dirty filters or debris
screen.
9. HEPA-Type filter needs
cleaning or replacing.
10. HEPA-Type filter frame
needs cleaning.
1. Clean dust cup. (page 7)
2. Adjust setting. (page 4)
3. Remove obstruction.
4. Remove power head cover and
remove o bs truc tion.
5. Remove obstruction.
6. Replace belt. (page 8)
7. Push hose in securely.
8. Clean / change filters or debris screen.
(page 7)
9. Clean or replace HEPA-Type filter.
(page 6)
10. Clean HEP A-Ty pe f il ter f rame. ( page 6)
Cleaner Picks
Up Moveable
Rugs Or Pushes
Too Hard
1. Wrong pile height setting. 1. Adjust setting. (page 4)
Agitator Does
Not Turn
1. Broken belt.
2. Belt installed incorrectly.
1. Replace belt. (page 8)
2. Check belt changing and agitator
cleaning. (page 8)
Air Flow
Restricted With
Attachment Use
1. Attachment use restricts air
flow.
2. New carpet debris clogging
air path.
1. Check attachment. (page 4)
2. Remove obstruction.
9
1. Poignée
2. Tige de verrouillage de la poignée
3. Tube extension
4. Boyau souple
5. Brosse à meubles
6. Suceur plat
7. Bouton de relâche de la poignée
8. Couvercle de la coupelle à
poussière
9. Bouton de relâche de la coupelle
10. Coupelle à poussière (réservoir)
11. Phare
12. Sélecteur de hauteur de tapis
13. Bouton de relâche de la poig née
14. Bouton d’alimentation On/Off
15. Garde-meuble
16. Étrangleur
17. Porte-tuyau
Spécifications techniques
Tension : 120 V, 60 Hz
Intensité : 12 A
*Avertissement : Les illustrations peuvent différer de l’appareil lui-même.
24