Sears 758.144131 Humidifier User Manual


 
Replacement and Care of Filters
WARNING: To reduce the risk of shock
or Injury from moving parts, always
unplug humidifier before removing or
replacing any parts.
CAUTION: To help retard bacteria
growth and keep maximum efficiency,
the filters should be replaced at least
once per season, or more often under
hard water conditions, Use Sears rec-
ommended replacement filter 42-14912.
All filters may be dnsed in deer water only,
Take care not to damage paper. To replace
evaperative wicking filters in your Kenmore
Quiet Comfort Whole House humidifier, fol-
low the Instructionsbelow.
1. Unplug humidifier and proceed to clean.
Before removing the fitters, we recom-
mend moving the humidifier to an area
where floor coverings are not suscepti-
ble to water damage, i.e. kitchen or bath
areas.
2. To remove parts
Remove the fan assembly by opening
the pivoting lid. Grasp the fan assem-
bly front center and rear center. Lift off
and set aside on a clean flat surface.
The filler housing assemblies are now
accessible.
NOTE: There are two filter housing
assemblies. Each assembly con-
elata of a top filter housing and a
front filter housing. The front filter
housing contains tabs that secure
the top filter housing. Do not
remove the front filter housings.
3. To remove top filter housing, deflect
the two vertical tabs on top of front fil-
ter housing and lift up and out of cabi-
net. With a soft, absorbent cloth
remove any remaining water or loose
mineral deposits not trapped in the fil-
ter from the filter housing assemblies.
4. Remove the two filters and dispose of
properly. Repeat for other top filter
housing. Clean internal parts of humid-
ifier per the =Cleaning of Humidifier"
section of this owner's manual.
Tab on
Front
Filter
Housln_
Top Rlter
Housln_
oa6Qo a_ a_
Pivoting
Lid
Fan
Roat
//_Retalner
Float
Front of Humidifier
(top view)