Sears 153.336631 Water Heater User Manual


 
Venting (cont'd)
WARNING
f Besurevent pipeisproperlyconnectedto preventescapeof
dangerousfluegaseswhichcouldcausedeadlyasphyxia|ion;
WARNING
Chemicalvapor corrosionof the flue and vent systemmay
occur if air for combustioncontainscertainchemicalvapors.
Spra ..canpropellants,. cleanin.g. solvents,refrig.erator and.air
con_tmner refrigerants,swwmmmgpool chemicals,caicmm
and sodiumchloride,waxes,bleachand processchemicals
aretypicalcompoundswhicharepotentiallycorrosive.
Caspiping
WARNING .......
Make surethe gassupplied is the sametype listed on the
modelratingplate.Theinletgaspressuremustnotexceed14
incheswatercolumn[½pound per squareinch(3.5kPa)].
WARNING
if thegascontrolValveissubjectedto pressuresexceeding½
poundper squareinch (3.5kPa),thedamageto thegas con-
trolvalvecouldresultin a fire or explosionfromleakinggas.
........... WARNING ......
if the maingaslineshutoffservingall gasappliancesis used,
alsoturn"OFF"the gasat eachappliance.Leaveallgasappli-
ancesshutoffuntilt-hewaterheaterinstallationiscomplete.
A gas line of sufficient size must be run to the water
heater. Consult the latest edition of National Fuel Gas
Code ANSI Z223.1, also referred to as NFPA54 and the
gascompany concerning pipe size.
There must be:
-A readily accessible manual shut off valve in the gassup-
ply line serving the water heater,and
A drip leg (sediment trap) ahead of the gas control valve
to help prevent dirt and foreign materials from entering
the gas control valve.
A flexible gas connector or a ground joint union between
the shutoff valve and control valve to permit servicing of
the unit.
Be sure to check all the gas piping for leaks before lighting
"thewater heater. Use a soapy water solution, hot a match
or open flame. Rinse off soapy solution and wipe dry.
Standard Models are for installation up to 3,300 feet
above sea level
High Altitude Models are for installation from 3,300 to
5,500 feet above sea level.
If astandard model is installed above 3,300 feet or a high
altitude model is installed above 5,500 feet, the input rat-
ing must be reduced at the rate of 4 percent for each
1,000 feet above sea level. Contact your local Sears
Service Center or gas utility for further information.
WARNING
The appliance and itsgas connection mustbe leak test-
ed before placingthe appliance in operation.
12
WARNING
Theapplianceanditsindividualshutoffvalvemustbe discon,
nectedfromthegassupplypipingsystemduringanypressure
testingof that systemat test pressuresin excessof ½ pound
persquareinch(3.SkPa).
'rheappliancemustbeisolatedfromthegassupplypipingsys.
ternby closingits individualmanualshutoffvalveduring any
pressuretestingof thegassupplypipingsystemat testpres-
suresequaltoor lessthan½poundpersquareinch(3.SkPa).
WARNING 1
Usepipe joint compoundor teflon tape marked as being
resistantto the actionof petroleum[Propane(L.P.)]gases.
Connecting the gas piping to the gas control valve of the
water heater can be accomplished by either of the two
methods shown.
GAS PIPING WITH FLEXIBLECONNECTOR
GAS SUPPLY PIPING
_ MANUAL SHUTOFF VALVE
GROUND JOINT
UNION (OPTIONAL)
FLEXIgLEGAS CONNECTOR
LABELEDAS COMPLYING
WITH ANSI STANDARDS
LOOP
GAS
CONTROL
VALVE
6" DRIP LEG
(SEDIMENT TRAP)
CAP
GAS PIPING WITH ALL BLACK IRON PIPE
TO GAS CONTROL
GAS SUPPLYPIPING
" MANUAL SHUTOFF VALVE
T
6" '
J_
GROUND JOINT UNION
BLACK P PE
GAS
CONTROL
VALVE
DRIP LEG
(SEDIMENT TRAP)
CAP
WARNING
Contaminants in the gas linesmay causeimproperopera-
tionof the gascontrol-valve that may resultin fire or explo-
sion.Beforeattachingthegasline be surethat all gaspipeis
cleanon the inside.Totrap any dirt or foreignmaterial in
the gassupplyline, a drip leg(sometimescalled a sediment
trap) mustbe incorporatedin the piping.Thedrip legmust
be readily accessible.Install in accordancewith the "Gas
Piping"section.Referto the latestedition of the National
FuelGasCode,ANSI Z223.1, alsoreferredto asNFPA54.