Sears 153.335903 Water Heater User Manual


 
Installation Instructions (cont'd)
USE WITHOUT POWER CORD (cont'd)
3. A standard ½" conduit opening has been made in the water
heater junction box for the conduit connection.
4. Use wire nuts and connect the power supply wiring to the
wires "ns'de the water heaters junction box.
5. The water heater must be electrically _grounded" by the
installer. A green ground screw has been provided on the
water heater's junction box. Connect ground wire to this
location. For complete grounding details and all allowable
exceptions, refer to the latest edition of the National
Electrical Code.
6. Replace the wiring junction cover using the screw
provided.
WIRING DIAGRAM
SgflT_4
S_T_H
Venting
_WARNING I
Toinsureproperventingofthisgas-Eredwater heater,the cot- I
rect vent pipe diameter must be utilized.Any additionsof I
other gas applianceson vent with this water heater will
adverselyaffecttheoperationofthe water heater.
The combustion and ventilation air flow must not be obstructed.
•,WARNING ,, I
The vent pipe from the water heater must be 3 diameter I
PVC schedule 40 pipe and must slope upward I/4 inch per
near foot.
All vent gases must be completely vented to the outdoors of the
structure (dwelling).
a_WARNING I
The water heater with draft hood installed must be properly I
vented to a chimney which terminates outdoors. Never oper-
_e the water heater unlessit isvented to the outdoors and has
adequate air supplyto avoidrisksof improper operation explo-
sion or asphyxiation.
&WARNING I
Obstructed or deteriorated vent systems may present a serious
health risk or asphyxiation.
Min. rise I/4"
perfoot
15
A,WARNING
Failureto haverequiredclearancesbetweenwater heaterand
combustiblematerialwillresult inafire hazard.