Sears 139.53930D Garage Door Opener User Manual


 
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot reach,
away from moving parts of door and door hardware.
If installing into drywall, drill 5/32" holes and use the
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 2).
1.Strip 7/16" (11 mm) of insulation from one end of bell
wire and connect to the two screw terminals on back of
door control by color: white wire to 2 and white/red wire
to the 1.
2. Remove cover by gently prying along one side with a
screwdriver (Figure 1). Fasten with 6ABx1-1/4"
self-tapping screws (drywall installation) or 6-32xl"
machine screws (into gang box) as follows:
Install bottom screw, allowing 1/8" (3 mm) to protrude
above wall surface.
Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
Drill and install top screw with care to avoid cracking
plastic housing. Do not overtighten.
Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated staples
to secure wire in several places. Do not pierce wire with
a staple, creating a short or open circuit.
4. Strip 7/16" (11 mm) of insulation from end of bell wire.
Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red.
Toprevent possible SERIOUSINJURYor DEATHfrom
electrocution:
Besure power is not connected BEFOREinstalling door
control.
ConnectONLYto 24 VOLTlow voltage wires.
Toprevent possible SERIOUSINJURYor DEATHfrom a closing
garage door:
Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m), and away
from all moving parts of door.
NEVERpermit children to operate or playwith door control
push buttons or remote control transmitters.
Activatedoor ONLYwhen it canbe seenclearly, is properly
adjusted,and there are no obstructions to door travel.
ALWAYSkeepgarage door in sight until completely closed.
NEVERpermit anyoneto cross path of closing garage door.
Outside Keylock Accessory Connections
To opener quick-connect terminals: white to white;
white/red to red.
Door Control Button
Control Console (std installation)
Control Console (pre-wired)
HARDWARE SHOWN
ACTUAL SIZE
Insulated
Staples
Drywall Anchors
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location
on inside of garage door.
NOTE: DO NOT connect power and operate opener at
this time. The trolley will travel to the full open
position but will not return to the close position
until the sensor beam is connected and properly
Figure I Figure 2
REMOVE & REPLACE COVER PRE-WIRED
INSTALLATION
To Replace,
Insert To Remove,
Top Tabs Twist
First Here
Lighted Quick-Connect
Push Butto__ 2-ConductorllWire Terminals
STANDARD
CONTROL CONSOLE
aligned.
Antenna
24 Volt
2-Conductor
Bell Wire
STANDARD CONTROL
'BACK VIEW)
Top
Mounting
Hole
Terminal
Screws
Bottom
Bell Mounting
Wire Hole
17