Schlage L-SERIES Door User Manual


 
20
SERIES
L
Electrified Locks
L9080PEL
L9080PEU
Applications: Security control centers, cashier rooms, fire safety
alarms, stairwell doors, telephone equipment rooms, computer
rooms, hospital equipment, and narcotics areas.
Regulating Devices: Security alarms, wall switches, security
consoles, access card readers, thermo-sensitive devices, smoke
and fire alarms, telephone access controls, automatic time
devices, and computerized controls.
All installations should be in accordance with local electrical
codes and National Electrical Code, NFPA 70-1996.
Electrical Requirements for EL or EU
Voltage: 24V AC or 24V DC (Maximum 29V, Minimum 20V)
Peak Current: Amps 1.3 at 5 to 10 second intervals
Holding Current: Amps .135 between peak current intervals.
Operating Temperature: Maximum +151°F, Minimum -31°F
Micro Switch Electrical Requirements for
Request to Exit (RX) Function
Amps, 1.0; Volts, 24 AC or DC
Peak load: Amps, 5; Volts, 250 AC or 28 DC
Replacement Kit
L283-053–Solenoid and Driver, EL or EU
Typical Installation
Electrified L-Series locks contain a transistorized circuit which
provides full voltage to the solenoid upon initial application of
electrical power and at 5 to 10 second intervals.
Each lock should preferably have its own 24 volt transformer.
Two or more locks may be operated in parallel from a single
transformer provided it has the necessary current rating.
NOTE: DO NOT connect locks in series from a higher volt-
age rated transformer.
We DO NOT recommend that these locks be connected to a
supply circuit that also contains electromagnetic devices. If an
electromagnetic device is connected to the supply circuit the
resulting transient voltages could damage the lock. The tran-
sient voltage must be carefully suppressed at the equipment
producing them before connecting the lock to the same cir-
cuit.
A varistor rated at 35 volts (peak recurrent) may be used for
transient voltage protection.
Typical Wiring Diagram for Electrified L-Series Locks
Frame to
Door Connector
(Not Furnished)
Varistor would
go here if used
(Not Furnished)
Switch
(Not Furnished)
Transformer
(Not Furnished)
24V AC 115V AC