5
Agitator Assembly
Motor Shaft
Flat Belt
REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the
power cord from the wall outlet before replacing any of the parts below.
REPLACING THE AGITATOR
Remove the bottom plate.
(refer to page 14)
Lift out the agitator assembly,and then remove the agitator assembly as shown.
Place the flat belt onto the pulley of the new agitator assembly.
Place the agitator assembly into the grooves in the nozzle head, making sure that the new
agitator assembly operate smoothly.
Caution:
Install the flat belt so that it has
no twists in it, and so that all
components turn smoothly.
Reattach the bottom plate
(refer to page 14)
13
Flat Belt
Pulley
Brush Holder