2. NOTICES FOR USER
5
Principle:
Air conditioner absorbs heat in the room and transmit to
outdoor and discharged, so that indoor ambient
temperature decreased. It's cooling capacity will decrease
by the increase of outdoor ambient temperature.
Anti-freezing Function:
If the units is running in COOL mode and in low
temperature, there will be frost formed on the heat
exchanger, when indoor heat exchanger temperature
decreased below 0 C, the indoor unit micro-computer will
stop compressor running and protect the unit.
2.1 Working Principle &
Special Functions
for Cooling
o
Operation and Maintenance
2.2 Working Temperature Range
2.3 The Conditions of Unit Can't Operate Normally.
In the following temp. range, the protection device may act, this may cause unit stop running.
The operating temperature range (outdoor temperature) for cooling unit is 21 °C ~ 52 °C.
Under the relative humidity is above 80% ( doors and windows are opened) when cooling or
dehumidifying for a long time, there may have dew drip off near the air vent.
COOLING
Temperature Indoor air temperature Outdoor air temperature
Max.
Min.
32 °C DB / 23 °C WB
21 °C DB / 15 °C WB
52 °C DB / ---
21 °C DB / ---
“COOL” running
“DRY” running
Outdoor temperature
above
Outdoor temperature
below
Indoor temperature
above
52°C 32°C
18°C 32°C
21°C
52°C