31
10.4 Tubing Length
Install unit within the maximum elevation
different (H) above or below the outdoor
unit and within a tatal tubing length (L)
from the outdoor unit as detailed showed
in Table 4 and Fig.37.
INDOOR
UNIT
Tubing length (L)
OUTDOOR
UNIT
Elevation
difference (H)
Fig. 37
10.5 Accessories
Table 5 listed the accessories supplied with the unit.
Table 4
*1 Standard tubing length is 5.0m.
*2 If total tubing length becomes 5.0m to 20 or 25 or 30m, charge additional refrigerant (R22) according
to table 4 above. No additional charge of compressor oil is necessary.
Model
Max. Allowable Tubing
Length at Shipment
(m)*
1
Limit of Tubing
Length (L)
(m)
Limit of Elevation
Different (H)
(m)
Required Amount of
Additional Refrigerant
(g/m)*
2
C18AP 5.0
7
30
25
C25AP 5.0
7
30
30
10. INSTALL OUTDOOR UNIT
Installation Service
C30AP 5.0
15
50
30
C12AP 5.0
5
20
20
Table 5
Parts Figure Q’ty Parts Figure Q’ty
Tapping
Screw
AAA alkaline
battery
2
Remote
Control Unit
5 1
1
10
Putty
1
4.2 x 25 mm
1
1
Ins. Tube
FAN
OPER
ONOFF
C
ON/OFF
FAN
- +
MODE
CLOCK
TIMER ON
BLOW TEMP
TIMER OFF
TURBO
SLEEP LIGHT
Power
Connection
Wire
0
Flare Nut
1
Power
Supply
Wire
*(K30AP only)
Model:
K9AP,K12AP
Models:
K18AP, K25AP, K30AP
1
Remote Control
Holder
(Optional)
*Only for specified model.
C9AP 5.0
5
20
15
*(K9AP, K12AP only)