Sanyo SAP-CMRV1926EH Air Conditioner User Manual


 
Table 2
–3–
NOTE
2.65:SAP-KRV96EHDS
3.5: SAP-KRV126EHDS
Room Room Room Room Room Room Room Room
A B C D Capacity ( Min. - Max.) A B C D Capacity ( Min. - Max. )
2.65
=
2.65 2.65 2.65 ( 1.4 - 3.2 ) 3.60 3.6 ( 1.8 - 4.7 )
3.5
=
3.5 3.50 3.5 ( 1.5 - 3.6 ) 4.20 4.2 ( 1.9 - 5.1 )
2.65 + 2.65
=
5.3 2.55 2.55 5.1 ( 2.0 - 5.8 ) 3.58 3.58 7.15 ( 2.3 - 8.1 )
2.65 + 3.5
=
6.15 2.41 3.19 5.6 ( 2.0 - 6.3 ) 3.42 3.98 7.4 ( 2.3 - 8.1 )
3.5 + 3.5
=
7 3.00 3.00 6.0 ( 2.0 - 6.3 ) 3.80 3.80 7.6 ( 2.3 - 8.1 )
2.65 + 2.65 + 2.65
=
7.95 2.08 2.08 2.08 6.25 ( 2.9 - 7.2 ) 2.63 2.63 2.63 7.9 ( 3.4 - 8.5 )
2.65 + 2.65 + 3.5
=
8.8 1.88 1.88 2.49 6.25 ( 2.9 - 7.2 ) 2.49 2.49 2.91 7.9 ( 3.4 - 8.5 )
2.65 + 3.5 + 3.5
=
9.65 1.72 2.27 2.27 6.25 ( 2.9 - 7.2 ) 2.37 2.77 2.77 7.9 ( 3.4 - 8.5 )
3.5 + 3.5 + 3.5
=
10.5 2.08 2.08 2.08 6.25 ( 2.9 - 7.2 ) 2.63 2.63 2.63 7.9 ( 3.4 - 8.5 )
2.65 + 2.65 + 2.65 + 2.65
=
10.6 1.56 1.56 1.56 1.56 6.25 ( 2.9 - 7.5 ) 2.00 2.00 2.00 2.00 8.0 ( 3.4 - 8.5 )
2.65 + 2.65 + 2.65 + 3.5
=
11.45 1.45 1.45 1.45 1.91 6.25 ( 2.9 - 7.5 ) 1.92 1.92 1.92 2.24 8.0 ( 3.4 - 8.5 )
2.65 + 2.65 + 3.5 + 3.5
=
12.3 1.35 1.35 1.78 1.78 6.25 ( 2.9 - 7.5 ) 1.85 1.85 2.15 2.15 8.0 ( 3.4 - 8.5 )
Total Performance
Single-room
Operation
3-room
Operation
4-room
Operation
Indoor Unit Capacity (kW)
COOLING HEATING
Total Performance
Indoor Unit Combination
2-room
Operation
When one or more SAP-KRVxxEHDS indoor units are operated concurrently with one or more SAP-KMRVxxEH
indoor units, the performance specifications of the SAP-KRVxxEHDS models will decrease by 5% from those listed in
the Table 2.
The table lists the wall-mounted type of indoor units as representative models.
For details on the connection of indoor units other than the wall-mounted type, refer to the catalog.
CombinationTable-2446EH.fm Page 3 Friday, September 26, 2008 10:20 AM