5. Address Switches
If you are installing one indoor unit or one group of
indoor units in the same room, it is necessary for you
to assign each unit its own address so that each can
be operated by its own remote control unit. You assign
the addresses by matching the switch position of each
indoor unit with the switch position of its remote control
unit. The switch of the remote control unit is shown in
Fig. 5-1.
5-1. Finding the Address Switches
Remove the lid by sliding it off. You can see the
switches inside the battery compartment. (Fig. 5-1)
(1) Turn off the Power Switch.
(2) Remove the Grille.
(3) Remove the cover of the Electrical Component
Box.
5-2.
Switch Positions for 2 Units or 2 Groups of Units
Table 5-1 shows the positions you can use for up to 2
units or 2 groups of indoor units installed in the same
room. Two remote control units are necessary to allow
the respective units or group to be controlled indepen-
dently.
An indoor unit cannot be controlled if its remote control
unit is too far away (more than 26 ft.). If the remote
control unit does not work correctly, bring it closer to
the unit being operated and try again. There should be
no obstacles between the remote control unit and the
indoor unit. For this reason, if the remote control unit is
to be used from a fixed position, check the operation
before mounting.
Fig. 5-1
Fig. 5-2
1008_M_I
Address switch is in “A” position
at time of shipment.
A
Address
B
Remote Control Unit
Indoor Unit
NOTE
Remote Control Indoor Unit
Unit No. Address switch Address switch
12
1 A OFF OFF
2 BONON
Table 5-1
Address Switch
(DSW1)
ON
1
2
1321_M_I
WIRED WIRELESS
R.C.U. Switch
P.C.B
The indoor unit address switch is set at 1-OFF & 2-OFF
position at shipment.