Sanyo KHS3082 + CH3082 Air Conditioner User Manual


 
Indoor Unit : KHS3682
Outdoor Unit : CH3682
Power Supply : 230V Single Phase 60Hz
< Heating Capacity >
TH : Total Heating Capacity (BTU/h)
1.
Rating conditions (#)
: Indoor Unit Entering Air Temp. 70 °F (21.1 °C) D.B.
: Outdoor Ambient Temp. 47 °F (8.3 °C) D.B. / 43 °F (6.1 °C) W.B.
2.
3. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air
Prevention Protection during heating operation into account. For this reason, the value may vary
from the actual heating characteristics.
NOTE
RATING CAPACITY: 36,000BTU/h AIR FLOW RATE: 671 CFM
OUTDOORINDOOR
ENT. TEMP.
o
F (
o
C)AMBIENT TEMP.
o
F (
o
C)
W.B. 60 65 70 75 80
(15.6) (18.3) (21.1) (23.9) (26.7)
0 (-17.8) TH 19,760 19,860 19,940 20,010 20,080
3 (-16.1) TH 20,420 20,510 20,600 20,670 20,740
8 (-13.3) TH 21,990 22,090 22,180 22,260 22,330
13 (-10.6) TH 23,630 23,730 23,830 23,920 23,990
18 (-7.8)TH25,44025,560 25,660 25,750 25,820
23 (-5.0)TH27,36027,480 27,590 27,680 27,140
28 (-2.2)TH29,37029,490 29,600 29,700 27,580
33 (0.6)TH31,46031,590 31,700 31,560 27,940
38 (3.3)TH33,54033,670 33,780 31,900 28,210
43 (6.1)TH35,76035,890 # 36,000 32,150 28,410
48 (8.9)TH38,03038,160 36,450 32,300 28,520
53 (11.7) TH 40,340 40,460 36,500 32,330 28,530
58 (14.4) TH 42,580 41,040 36,420 32,230 28,430
63 (17.2) TH 44,920 40,770 36,160 32,000 28,210
65 (18.3) TH 45,520 40,610 36,020 31,870 28,090
28