Sanyo KHS1251 Air Conditioner User Manual


 
32
COOLING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V Single phase 60Hz
Rating Conditions Running Amps. A 0.25 / 0.23 0.49 / 0.46 6.86 / 7.41 7.6 / 8.1
Power Input kW 0.047 / 0.045 0.113 / 0.095 1.54 / 1.52 1.70 / 1.66
Full Load Conditions Running Amps. A 0.25 / 0.23 0.49 / 0.46 8.8 / 9.7 9.5 / 10.4
Power Input kW 0.047 / 0.045 0.113 / 0.095 1.98 / 1.98 2.14 / 2.12
Rating Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor Air Temperature 115°F (46.1°C) D.B.
HEATING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 230 / 208V Single phase 60Hz
Rating Conditions Running Amps. A 0.25 / 0.23 0.49 / 0.46 6.36 / 6.81 7.1 / 7.5
Power Input kW 0.047 / 0.045 0.113 / 0.095 1.45 / 1.40 1.61 / 1.54
Full Load Conditions Running Amps. A 0.25 / 0.23 0.49 / 0.46 8.6 / 9.4 9.3 / 10.1
Power Input kW 0.047 / 0.045 0.113 / 0.095 1.94 / 1.92 2.10 / 2.06
Rating Conditions : Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.
Indoor Unit KHS1852
Outdoor Unit CH1852