6. ELECTRICAL DATA
6-1. Electrical Characteristics
COOLING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 115V Single phase 60Hz
Rating Conditions Running Amps. A 0.40 0.70 7.4 8.5
Power Input kW 0.034 0.081 0.775 0.89
Full Load Conditions Running Amps. A 0.40 0.70 9.1 10.2
Power Input kW 0.034 0.081 0.985 1.10
Rating Conditions : Indoor Air Temperature 80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.
Outdoor Air Temperature 95°F (35°C) D.B.
Full Load Conditions : Indoor Air Temperature 95°F (35°C) D.B. / 70°F (21.2°C) W.B.
Outdoor Air Temperature 115°F (46.1°C) D.B.
HEATING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 115V Single phase 60Hz
Rating Conditions Running Amps. A 0.40 0.70 7.3 8.4
Power Input kW 0.034 0.081 0.775 0.89
Full Load Conditions Running Amps. A 0.40 0.70 8.6 9.7
Power Input kW 0.034 0.081 0.935 1.05
Rating Conditions : Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.
Indoor Unit KHS0951
Outdoor Unit CH0951