Sanyo KH3672R / C3672R Air Conditioner User Manual


 
1
2
3
4
5
6
I-37
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. KH2672R
Source 230 - 208 V / 1 phase / 60 Hz
Remote controller (Option) Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y CB - KR24GXH56A
Control circuit fuse 250 V, 5 A
Fan Cross-flow
Number ... Dia. and length in. (mm) 1 ... O.D. 4-1/3 (110), L39 (990)
Fan motor
Model KFT4Q - 31A6P - C
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole ... r.p.m. (230 V, High) rpm 4 ... 1,224
Nominal output W 28.8
Coil resistance BRW - WHT : 260.7 , ORG - YEL : 23.76
(Ambient temperature 68 °F) WHT - VLT : 42.62 , YEL - PNK : 115.9
VLT - ORG : 30.36 ,
Safety device
Operating temperature Open °F ± 14.4
Close °F 174.2 ± 26
Run capacitor VAC, µF 440 V , 1.8 µF
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows ... Fins per inch 2 ... 24.1
Face area ft.
2
(m
2
) 2.57 (0.24)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
266