INSTALLING THE OUTDOOR UNIT
Auxiliary Circuit Breaker
Electrical Work
1 The supply voltage must be the same as the rated voltage of the
air conditioner.
2 Prepare the power souce for exclusive use with the air conditioner.
3 Use 20 amperes time delay fuse or circuit breaker.
When using the special NFB, use the NFB to bear the capacity of the
air conditioner.
Otherwise, the shot circuit in the NFB may occur.
Outdoor unit
Distribution
board
Auxiliary
power s/w
Auxiliary circuit breaker should be installed near outdoor unit so
that each access is possible. Main/outdoor power supply cable are
connected to upper/lower terminal of auxiliary circuit breaker.
It is necessary that the conduit kit for power supply to the outdoor
unit be installed between auxiliary power S/W and the outdoor
unit. (the conduit kit is optional)
The designs and shape are subject to
change according to the model.
MODEL
AM26B1C13
AM27B1C07
AM27B1C13
Power supply
Power cable
Assembly cable
Operating current
Starting Current
Power consumption
208-230V~/60Hz
AM18B1C09
3G AWG 14
4G AWG 16
11.6A
2580W
31A31A
11.4A
22A
8.4A
2550W1920W