Samsung AM27B1C13 Air Conditioner User Manual


 
Technical Specifications
E-24
Standard rating conditions Cooling
Indoor
DB
80
26.7
°F
°C
WB
67
19.4
DB
95
35.0
WB
75
23.9
Outdoor
10.0 10.0
MODEL
Performance
Ratings
Capacity Cooling
SEER
Moisture Removal
Air FLOW(Cooling, HIGH)
Sound Rating-Outdoor
Btu/h
Pts/h
CFM
dB
Electrical
Data
The number of operation
Power source
Min.Ampacity
Cooling Watts
A
W
Refrigeration
Lines
Indoor unit
Connections
Liquid Line O. D.
Suction Line O.D.
Factory Pre-charge
Max. Line length
Max. Height Difference
mm(in)
mm(in)
m(ft)
m(ft)
m(ft)
Dimensions
& Weight
W X H X D
Net Weight
mm(in)
Ibs
6.35 (1/4)
790 x 245 x 165
16
1
2
)(
17 132.3 17 152.1
7.0 (23) 7.0 (23)
9
1
2
31
1
8
xx
6
1
2
880 x 638 x 310
)
(
25
1
8
34
1
2
xx
12
1
4
790 x 245 x 165
)
(
9
1
2
31
1
8
xx
6
1
2
1000 x 790 x 310
)(
31
1
8
39
1
2
xx
12
1
4
Indoor unit Outdoor unit Indoor unit Outdoor unit
Type
AM18B1C09 UM18B1C2 AM26B1C13 UM26B1C2
2 Comp + 2 Room 2 Comp + 2 Room
A/B-Unit : 9000 A/B-Unit : 12500
3-4-
255 - 300 -
-
57 - 60
1 Unit operation 2 Unit operation 1 Unit operation 2 Unit operation
208-230V~,60Hz
208-230V~,60Hz
9.52 (3/8) 12.70 (1/2)
6.35 (1/4)
4.3
990
8.4 6.1 11.4
1920 1360 2550
A-Unit
B-Unit A-Unit B-Unit
Flare Flare
5.0 ( )
16
1
2
5.0 ( )
49
1
4
15.0 ( )
49
1
4
15.0 ( )