Step 3: Testing the Thermostat
WARNING:DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL
TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY.
CAUTION: D
O NOTSWITCH SYSTEM TOCOOL IF THETEMPERATURE ISBELOW 50°F (10°C). THISCAN DAMAGE
THE AIRCONDITIONING SYSTEM ANDCAUSE PERSONAL INJURY
.
1. Place the COOL-OFF-HEAT-EM
switch into the COOL position
2. Press the button until the temperature
setting is at least 3 degrees below the room temperature. The air
conditioning system should turn on within a few seconds.
NOTE: O
NCETHE THERMOSTATTURNSTHE SYSTEMOFF WHILEIN THECOOLOR HEATMODE
,
ABUILT
-
INDELAYKEEPS THECOM
-
PRESSORFROM TURNINGON FORABOUT
5
MINUTES
. T
HISPROTECTS THECOMPRESSOR
. N
OADDITIONAL TIMEDELAYRELAY
(
DELAYON
BREAK
)
ISNECESSARY
. T
OOVERRIDE THE
5-
MINUTEDELAYFOR INSTALLATION
,
PRESS
RESET. T
HISWILL ERASETHE DELAYASWELL
ASALL PROGRAMMING
.
3. Put the COOL-OFF-HEAT-EM switch into
the OFF position. The air conditioning
system should turn off. The fan may
continue to run for a short period of time.
4. Put the COOL-OFF-HEAT-EM switch
into the HEAT position.
5. Press the button until the temperature setting is at least
3 degrees above room temperature. The heating system should turn
on. The fan may not turn on immediately, depending on the fan delay
built into the furnace.
6. Put the COOL-OFF-HEAT-EM switch
into the OFF position. The heating
system should turn off. Once again,
the fan may have a delay.
7. Put the AUTO-ON switch
to the ON position. The blower
fan should turn on.
8. Put the AUTO-ON switch
to the AUTO position. The blower
fan should turn off.
7
COOL-OFF-HEAT-EM
COOL-OFF-HEAT-EM
COOL-OFF-HEAT-EM
COOL-OFF-HEAT-EM
AUTO - ON
AUTO - ON
>
>