12. Terminal screws are already loose and ready for wire insertion.
Insert wires into terminal strip (Figure 5) matching the label to the
corresponding terminal (see Wiring Diagrams below). Tighten
screws.
13. Make sure wire connections are secure.
14. Push access wire back through opening.
5
O
Y1
E
B
G
W2
Y2
E
Figure 5