Rinnai RHFE-750ETR Indoor Fireplace User Manual


 
24 Rinnai Corporation RHFE-750ETR
6. Unscrew the flue access panel held by two
screws located inside the top left-hand corner of
the appliance. Slide this panel to the right behind
the convection fan.
Connections
1. Carefully remove the packaged ceramic logs and
place in a safe location.
2. To ensure the correct positioning, terminate the
gas supply so that it is 5.9 inches (150 mm) from
the front of the enclosure.
3. Gain access to the gas connection by removing
the right hand side access panel by unscrewing
the four retaining screws. Pry the front edge of
the panel open to the right and pull forwards.
4. Position the appliance in front of the enclosure so
that the end of the gas supply aligns with the gas
fitting opening. Connect the flexible gas
connection to the gas supply.
5. Replace the right hand panel and secure with the
four retaining screws.
7. Attach the electrical connection and place in the
junction box.
8. Leak test the gas connection using a soapy
solution. Do not allow the soapy solution to
contact electrical components. Remove any
residue.
gas fitting opening gas connection
remove 4
screws to
remove
side
panel