Rheem 300 series Water Heater User Manual


 
INSTALLATION
18
DIMENSIONS AND TECHNICAL DATA
Model
300 135
620 130
300 170
Storage capacity
litres
135 170
Mass (tank) Empty
kg
54 63
Full
kg
189 233
Dimensions
A B C D E F G H K L M
130 / 135
mm
1615 425 500 988 328 297 1490 58 490 213 75
170
mm
1915 425 500 1213 403 297 1790 58 490 213 75
Gas Details
Hourly Gas
Consumption (MJ)
Min. Gas
Pressure (kPa)
Test Point Gas
Pressure (kPa)
Max. Gas
Pressure (kPa)
130, 135 170 130 to 170 130, 135 170 130 to 170
Natural 30 30 1.13 1.00 1.00 3.50
Propane 30 30 2.75 2.70 2.70 3.50
Butane 25 25 2.75 2.70 2.70 3.50
Town / TLP 29/27 29/27 0.75 0.44 0.44 3.50
Model numbers: N = Natural, P = Propane, B = Butane, T = Town / TLP. Letter N, P, B or T is
included in the model number, eg 300135N0, to denote gas type.
Specifications are subject to change with ongoing product improvements.