Troubleshooting
THERMOSTAT AND GAS SUPPLY CHECK
Is thermostat calling for heat?
Run (hot) water from heater and
turn adjustment knob higher.
Check using a manometer at
thermostat pressure tap.
Is there a minimum gas pressure
4 W.C. for natural gas or 10
W.C. for propane (L.P.) gas?
GO TO SYSTEMS CHECK
SECTION, PAGE 32
Turn “ON” gas supply.
Call gas company to increase
gas pressure.
Yes
Yes
Yes
No
Is gas being supplied to the
thermostat?
No
WARNING
This troubleshooting guide has been supplied for use by
qualified service personnel who have a complete under-
standing of both electricity and gas.
WARNING
Label all wiring before disconnecting any wiring; to
ensure correct reconnection. Failure to follow this
instruction could cause improper and possible danger-
ous operation, resulting in DEATH, SERIOUS BODILY
INJURY, OR PROPERTY DAMAGE.