Reliable i500B Carpet Cleaner User Manual


 
USER INSTRUCTIONS i500
Thank you for purchasing the Reliable™ i500 series iron system. Please
follow the instructions carefully. With proper care and maintenance, your
steamer will provide years of dependable service.
1. Remove the ironing station from its packing and make sure all packing
parts have been taken off (including the protection bags). Lay the
station on a flat and steady surface fitted to support it next to a wall
socket (max. mt. 1,5).
2. It is recommended to lay the iron on the supplied pad.
3. Insert in the right seat (2) the small supplied wand to hold the hose up
and hook it with the spring up to the iron-boiler connecting wire.
4. Unscrew the safety cap (1) and let the internal air out. Fill the boiler
with: Max. 2,0 litres of water for model i500
Use the funnel supplied, making sure you do not overfill the tank.
5. Insert the plug into the main supply point; switch on boiler (4) and iron
button (3). If the two buttons come on, iron and boiler are working.
6. Turn the iron plate’s temperature regulating knob (6) to the position
“cotton °°°” (indicated on the iron knob).
7. Wait that the boiler button’s red light (4) goes off (it takes about 10
minutes). While ironing, the boiler button’s red light normally comes on.
8. The machine is ready for use.
9. Push the steam button (7).
10. It is possible to regulate the quantity of steam by the steam knob (8).
11. In case the steam stops during ironing and the water button’s red light
(5) comes on, it means that there is not enough water in the tank. To
start ironing again, switch off the boiler button (4); press the steam iron
button (7) to ensure there is no more steam in the boiler, slowly open
the pressure cap (1) and refill to the required level with warm water.
Replace the cap and wait for it to build up pressure again.
12. When you first press the steam button (after having turned the boiler
on and depressed the steam button on the iron) you might notice a
decrease in pressure. This is because the tank has air in it. In order to
have plenty of steam (after you have depressed the iron) wait until the
pressure goes back up to the maximum level before you begin.
IMPORTANT
When you are finished using the boiler for the day, unscrew the fill cap one-
turn on the unit to release the steam/air from the tank. This will eliminate the
vacuum that may cause damage to the pressure gauge.