Regency P42-NG3 Indoor Fireplace User Manual


 
Regency P42-3 Zero Clearance Direct Vent Gas Fireplace
10
INSTALLATION
VENTING
Regency Direct Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with
the P42 Direct Vent Gas Fireplace, have been
tested and listed as a direct vent heater system
by Warnock Hersey. The location of the termi-
nation cap must conform to the requirements
in the Vent Terminal Locations diagram on
page 9.
Regency Direct Vent (Flex) System Ter-
mination Kit (Part # 946-515) includes all
the parts needed to install the P42 with
a maximum run of 4 feet.
1) 6-7/8" dia. flexible liner (4 ft. length)
2) 4" dia. flexible liner (4 ft. length)
3) spring spacers (4)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1/2" Drill Point, stainless steel
(4)
If longer runs are needed, the Regency
Direct Vent system (Flex) # 946-516 in-
cludes all the parts needed to install the
P42 with a maximum 10' run.
1) 6-7/8" dia. flexible liner (10 ft. length)
2) 4" dia. flexible liner (10 ft. length)
3) spring spacers (7)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1/2" Drill Point, stainless steel
(4)
Note:
a) Liner sections should be continuous with-
out any joints or seams.
b) Only Flex pipe purchased from Regency
may be used for Flex Installations.