Regency P121/P131-NG2 Indoor Fireplace User Manual


 
Horizontal Venting with Two (2) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Option V H+ H1 Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 15 feet.
Minimum of 1 foot between
90° elbows is required.
A) 1’ Min. 2’ Max.
B) 2’ Min. 5’ Max.
C) 3’ Min. 8’ Max.
D) 4’ Min. 11’ Max.
E) 5’ Min. 14’ Max.
F) 6’ Min. 15’ Max.
Horizontal Venting with Two (2) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option H V H + H1 Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.
A) 1’ Max. 1’ Min. 3’ Max.
B) 3’ Max. 2’ Min. 6’ Max.
C) 5’ Max. 3’ Min. 9’ Max.
D) 8’ Max. 5’ Min. 12’ Max.
Horizontal Venting with Three (3) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Option V+ V1 H + H1 Maximum total pipe: length,
of all sections, must not
exceed 37 feet.
Total horizontal sections
must not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.
A) 2’ Min. 3’ Max.
B) 3’ Min. 6’ Max.
C) 4’ Min. 9’ Max.
D) 5’ Min. 12’ Max.
Horizontal Venting with Three (3) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option H V H + H1 + H2 Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between
90° elbows is required.
A) 1’ Max. 2’ Min. 3’ Max.
B) 3’ Max. 3’ Min. 6’ Max.
C) 5’ Max. 4’ Min. 9’ Max.
F) 7’ Max. 5’ Min. 12’ Max.
P121-P131 Gas Fireplace
75June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fireplaces