Regency P121/P131-NG2 Indoor Fireplace User Manual


 
Vertical Venting with Two (2) 90° Elbows
- Initial vertical section.
Two 45° elbows = One 90° elbow
Option V+ V1 H Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 17 feet.
Minimum of 1 foot between
90° elbows is required.
A) 1’ Min. 4’ Max.
B) 2’ Min. 6’ Max.
C) 3’ Min. 9’ Max.
D) 4’ Min. 12’ Max.
E) 5’ Min. 15’ Max.
E) 6’ Min. 17’ Max.
Vertical Venting with Two (2) 90° Elbows
- Initial horizontal section.
Two 45° elbows = One 90° elbow
Option H + H1 V Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 8 feet.
Minimum of 1 foot between
90° elbows is required.
A) 2’ Max. 1’ Min.
B) 4’ Max. 2’ Min.
C) 6’ Max. 3’ Min.
D) 8’ Max. 4’ Min.
Vertical Venting with Three (3) 90°
Elbows - Initial vertical section.
Two 45° elbows = One 90° elbow
Option V+ V1 H + H1 Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must not
exceed 12 feet.
Minimum of 1 foot between 90°
elbows is required.
A) 2’ Min. 3’ Max.
B) 3’ Min. 6’ Max.
C) 4’ Min. 9’ Max.
D) 5’ Min. 12’ Max.
Vertical Venting with Three (3) 90°
Elbows - Initial horizontal section.
Two 45° elbows = One 90° elbow
Option V+ V1 H H + H1 Maximum total pipe: length, of
all sections, must not exceed
37 feet.
Total horizontal sections must
not exceed 12 feet.
Minimum of 1 foot between 90°
elbows is required.
A) 2’ Min. 1’ Max. 2’ Max.
B) 3’ Min. 4’ Max. 5’ Max.
C) 4’ Min. 6’ Max. 8’ Max.
D) 5’ Min. 8’ Max. 12’ Max.
P121-P131 Gas Fireplace
73June 2007 Regency Product Specifi cations Book