P121 - P121LC/RC - P131 Zero Clearance Direct Vent Gas Fireplace
Model P121/P131-NG2 P121/P131-LP2
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa)
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifi ce Size #31 DMS #50 DMS
Minimum Input 20,500 BTU/h (6.01 kW) 20,600 BTU/h (6.04 kW)
Maximum Input 40,000 BTU/h (11.72 kW) 39,000 BTU/h (11.43 kW)
Vent Sizing 4” Inner / 6-5/8” Outer 4” Inner / 6-5/8” Outer
P
Gas Line
Inlet
Electrical
Inlet
BACK
N
O
M
A
D
C
G
E
B
F
P121 See Thru P131 Pier
P121RC Right Corner P121LC Left Corner
Unit Dimensions Description P121 P121LC/RC P131
A Front Face Width
43-1/2”
(1105mm)
41-1/2”
(1054mm)
41-1/2”
(1054mm)
B Total Firebox Width
46-1/4”
(1175mm)
44-1/2”
(1130mm)
44-1/2”
(1130mm)
C Front Face Height 36” (914mm) 36” (914mm) 36” (914mm)
D Height w/ Standoff 42” (1067mm) 42” (1067mm) 42” (1067mm)
E Unit Depth 25” (635mm)
26-13/16”
(681mm)
25” (635mm)
F Top Offset Depth
21-1/8”
(537mm)
21-1/8”
(537mm)
21-1/8”
(537mm)
G Inset to Standoff
4-3/4”
(121mm)
4-3/4”
(121mm)
3” (76mm)
H
I
J
K
Combustible
Material
3”
Extension
Trim
Non-Combustible
Material *
To po f
Unit
8”
Greyed out framing will not apply to all units.
Please refer to the manual.
L
Framing Dimensions Description P121 P121LC/RC P131
H Framing Width
46-3/4”
(1187mm)
45”
(1143mm)**
45”
(1143mm)**
I** Framing Height **
42-1/2”
(1080mm)
42-1/2”
(1080mm)
42-1/2”
(1080mm)
J
** Framing Depth** 25” (635mm)**
26-13/16”
(681mm)
25” (635mm)
**
K Vent Centerline Height 42-13/16” (1072mm)
L Framed Chase Ceiling 48-1/4” (1226mm)
M Electrical Inlet Height 2” (51mm) 2” (51mm) 2” (51mm)
N Electrical Inlet Inset
11-3/8”
(289mm)
13-5/16”
(338mm)
11-3/8”
(289mm)
O Gas Connection Height
1-11/16”
(43mm)
1-11/16”
(43mm)
1-5/8” (41mm)
P Gas Connection Inset
11-1/2”
(292mm)
11-1/2”
(292mm)
11-1/2”
(292mm)
** Refer to the manual for variations effected by fi nishing material
thickness.
P121-P131 Gas Fireplace
If the provided 3” extension trim is not installed the P121(LC/RC)/
P131 must be installed with non-combustible facing up to 8” above
the fi replace. Otherwise combustible facing may be used above the
extension trim.
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
69June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fireplaces