FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 5
INSTALLATION AND REPAIRS
SHOULD BE DONE BY AN AUTHOR-
IZED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY
BY AN AUTHORIZED SERVICE PER-
SON. MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPET-
ING, ETC. IT IS IMPERATIVE THAT
THE CONTROL COMPARTMENT,
BURNERS AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLI-
ANCE BE KEPT CLEAN.
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The REGENCY Rear Flued Room Sealed Free-
standing Gas Stove must be installed in accord-
ance AG601 and NZS 5261 and with these
instructions. Carefully read all the instructions
in this manual first. Consult the building authority
having jurisdiction to determine the need for a
permit prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your
fire insurance and/or warranty.
SPECIFICATIONS
Fuels: FG37-NG is approved for use with
NG.
FG37-LPG is approved for use with
liquefied petroleum gases (LPG).
Electrical: 240 V A.C. system.
Circulation Fan: Two Speed
Log Sets: Ceramic fibre, 7 per set.
Flue System:
Axial (6-5/8" (168mm) outer / 4"
(102mm) inner liner) rigid flue and
Riser Vent Terminal.
Safe installation and operation of this appliance
requires common sense, however, please be
aware of the following:
INSTALLATION
4) We recommend that you plan your installa-
tion on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have an
authorized building inspector review your
plans before installation.
GENERAL SAFETY
INFORMATION
1) The appliance shall be installed in accord-
ance with the manufacturer's installation
instructions, local gas fitting regulations,
municipal building codes, water supply reg-
ulations, electrical wiring regulations, with
AS5601-2004 (AGA gas installation code)
NZS 5261 (New Zealand)
2) Installation and repair should be done
ONLY by an authorised person.
3) DO NOT CONNECT TO MASONARY FLUE.
4) This appliance must be connected to
the specified flue and termination cap
to the outside of the building enve-
lope. Never flue to another room or
inside a building. Make sure that the
flue is fitted as per Flueing instruc-
tions.
5) Inspect the flueing system annually for
blockage and any signs of deterioration.
6) Flueing terminals shall not be recessed into
a wall or siding.
7) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
9) Wear gloves and safety glasses for pro-
tection while doing required maintenance.
10)Be aware of electrical wiring locations in
walls and ceilings when cutting holes for
termination.
11)Under no circumstances should this appli-
ance be modified. Parts that have to be
removed for servicing should be replaced
prior to operating this appliance.
12)Installation and any repairs to this appliance
should be done by an authorised service
person. An authorised service person
should be called to inspect this appliance
annually. Make it a practice to have all of
your gas appliances checked annually.
13)Do not slam shut or strike the glass door.
DUE TO HIGH TEMPERATURES,
THE APPLIANCE SHOULD BE LO-
CATED OUT OF TRAFFIC AND
AWAY FROM FURNITURE AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY
WILL VOID YOUR WARRANTY AND
MAY CAUSE A SERIOUS HOUSE
FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE
GLASS, AND SHOULD STAY AWAY
TO AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.
1) Provide adequate clearances for servic-
ing, proper operation and around the air
openings into the combustion chamber.
2) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or it can
be raised up on a platform to enhance its
visual impact. The appliance may be in-
stalled on carpeting, tile, wood flooring or
other combustible material, because the
appliance's metal pedestal base extends
the full width and depth of the appliance.
The REGENCY Rear Flued Room Sealed
Freestanding Gas Stove can be installed in
a wide variety of ways and will fit nearly
any room layout. It may be installed in a
recessed position, framed out into the room,
or across a corner.
3) The REGENCY Rear Flued Room Sealed
Freestanding Gas Stove is approved for
manufactured home installations, see pag-
es 6 to 9 for the required flue arrangements.
If installed into a manufactured home the
unit must be bolted down to the floor.