Regency CLASSIC C33-2 Freestanding Gas Stove 7
Diagram 4
9) Lift the fan assembly in through the pedes-
tal and up through the cut out as shown in
diagrams 3 and 4.
10)Put the insulation gasket on the back of the
fan. Line up the keyhole slots with the
matching screws and pull back slightly to
lock into place. While holding fan assembly
in place, tighten screws.
Diagram 3
Diagram 2
OPTIONAL FAN
INSTALLATION
Important: Disconnect the power
supply before installation or servic-
ing.
For pedestal unit: To install the fan in an
installed stove-access from front through
the pedestal by following the directions
below. If the stove is not installed - access
through rear and follow steps 4 to 17.
Diagram 1
INSTALLATION
CLEARANCES TO
COMBUSTIBLES
The clearances listed below are MINIMUM dis-
tances. Measure the clearance to both the
appliance and the chimney connector. The
farthest distance is correct if the two clearanc-
es do not coincide. For example, if the appliance
is set as indicated in one of the diagrams but the
back wall is too close, move the stove until the
correct clearance to the back wall is obtained.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with the
unit) is installed.
This appliance may be installed only with the
clearances as shown in the situations pic-
tured. Do not combine clearances from one
type of installation with another in order to
achieve closer clearances. Use the minimum
clearances shown in the diagrams. Alcove
installations are approved, as long as side wall
clearances are maintained.
C33-2 Clearances to Combustibles
A Side Wall to Unit 10" / 250 mm
B Back Wall to Unit 6" / 150 mm
E Side Wall to Unit 1.5" / 38 mm
C33-2 Reference Dimensions
to Flue Centerline
C Back Wall 11-1/2"/ 292 mm
D Side Wall 22" / 559 mm
F Side Wall 13" / 330 mm
Minimum ceiling height is 36" / 914 mm
from top of unit.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15-20 min. to
stabilize.
3) Check for proper draft.
CAUTION: Any alteration to the prod-
uct that causes sooting or carbon-
ing that results in damage is not the
responsibility of the manufacturer.
For leg unit: remove 7 screws, remove
bottom access panel and install fan as-
sembly and follow steps 4 to 17.
1) Open pedestal door and remove door cov-
er plate by removing 4 screws. See dia-
gram 1.
2) Remove valve cover plate by removing 2
screws.
3) Remove wire from piezo ignitor.
4) Screw the four 8-32 x 3/4 screws provided
into the nutserts as shown in diagram 3. Do
not tighten screws.
5) Push all the fan wires through the hole on
the fan assembly. See diagram 2
.
6) Put power cord (shown in diagram 3)
through the hole and pull through to front of
unit for easier installation of ground wire.
7) Place fan assembly partially in door cover
plate hole. See diagram 2.
8) Attach the 2 ground wires (green) to the
ground lug as per diagram 2.
Note: Ground lug is located on the bottom
of the fan assembly. See diagram 2.