Regency C33-LP2 Stove User Manual


 
4
Regency CLASSIC C33-2 Freestanding Gas Stove
This is a copy of the label that accompanies
each CLASSIC Freestanding Gas Stove - Nat-
ural Gas. We have printed a copy of the
contents here for your review. The safety label
is located on the back panel.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.
SAFETY LABEL
Listed: GAS FIRED VENTED ROOM HEATER
Certified for:
Report No.
CANADA and USA
476-1345-00 (Oct. 1996)
FPI Fireplace Products International Ltd.
Delta, BC, Canada
FACTORY EQUIPPED FOR NATURAL GAS:
Model C33-NG2
Minimum supply pressure 5" WC/C.E. (1.25Kpa)
Manifold pressure High 3.8" WC/C.E. (0.94Kpa)
Manifold pressure Low 1.1" WC/C.E. (0.27Kpa)
Orifice size 36 DMS
Altitude 0-2000 ft/pi (0-610 m)
Maximum Input 33,000 BTUH (9.67Kw/h)
Minimum Input 17,000 BTUH (4.98Kw/h)
Factory Equipped for 0-2000 ft.
Minimum supply pressure 5" WC/C.E. (1.25Kpa)
Manifold pressure High 3.8" WC/C.E. (0.94Kpa)
Manifold pressure Low 1.1" WC/C.E. (0.27Kpa)
Orifice size 38 DMS
Altitude 2000-4500 ft/pi (610-1370m)
Maximum Input 29,000 BTUH (8.5Kw/h)
Minimum Input 15,300 BTUH (4.48Kw/h)
Serial No.
201
HIGH ALTITUDE CONVERTED NATURAL GAS:
Model C33-NG2
Field Convertable for Altitude 2000-4500 ft.
(Report No.476-1345-00)
Made in Canada
908-634a
DO NOT REMOVE THIS LABEL
Minimum Clearances to Combustibles
Back wall
Side wall
E
A - 10"
E - 1.5"
Minimum ceiling height from top of unit: 36"/914mm
A
A
B
Back wall
Side wall
Side wall
GAS FIRED VENTED ROOM HEATER
This appliance must be installed in accordance
with local codes, if any; If not, follow:
ANSI Z223.1/CAN 1-B149.
Electrical Supply (115 V, 1.13 A, 60 Hz)
Not for use with solid fuel.
Optional Fan: (Part #490-917)
B-6"
Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003,
CAN/CGA-2.17-M91
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.