18
Regency CLASSIC C33-2 Freestanding Gas Stove
MAINTENANCE
8) If optional fan is installed, remove thermo-
disc to bracket by removing three (3) phillips
head M5 screws.
9) Remove front cover with Piezo Igniter by
removing two (2) sheet metal screws.
10)Loosen four (4) phillips head M5 valve
mounting screws from underside of fire-
box. Push valve assembly forward on the
teardrop slots and drop down. Diagram 3.
Diagram 1
Diagram 2
4) Disconnect gas line to stove.
5) Disconnect 3/8" NPT pipe from 90
o
elbow on
valve.
6) Disconnect the two (2) switch wires from
valve.
7) Remove two (2) orifice bracket screws
inside firebox.
Diagram 3
REMOVING VALVE
ASSEMBLY
1) Shut off gas supply.
2) If optional fan is installed, disconnect pow-
er source to stove.
3) Remove access panel.
a) Front panel on pedestal model. See
diagram 1.
b) Panel from bottom of leg shield. See
diagram 2.
Note: Access panel only has to be loos-
ened to be taken out.
11)Disconnect Piezo wire.
To remove valve from valve assembly,
continue.
12)Remove two (2) thermopile wires.
13)Remove thermocouple with a 9 mm (met-
ric) wrench.
14)Remove pilot nut with an 11 mm wrench.
15)Remove valve to orifice nut with a 13/16"
wrench.
16)Remove inlet pipe with pipe wrench. Note
orientation of 90
o
elbow.
17)Remove two (2) phillips head M5 screws on
each side of the valve.
18)Remove valve and remove gas out 90
o
brass fitting. Note orientation of fitting.
INSTALLING VALVE
ASSEMBLY
1) To install a new valve assembly, reverse
instructions for removing valve. See
assembly steps 1-11.
2) Check for leaks and manifold pressure. See
Gas Pressure Test instructions.
3) To reinstall valve, reverse instructions for
removing valve assembly, steps 12-18.