Raypak RFSDV34RFNAU Indoor Fireplace User Manual


 
Gas Specifications
Model Gas Type Gas Control Min. MJ/h
Input
Max. MJ/h
Input
RFSDV34RFN Natural Radio Freq. 22 32
RFSDV34RFP Propane Radio Freq. 24 32
Gas Inlet and Burner Pressures
Natural Gas ULPG
Inlet Minimum 1.1 kPa 2.75 kPa
Inlet Maximum 3.50 kPa 3.50 kPa
Burner Pressure 0.87 kPa 2.50 kPa
Preparation
Warning: The use of wall paper adjacent to this fireplace is not
recommended, as the heat produced by this appliance may adversely
affect the binders in the adhesive used to apply the wall paper.
Before beginning, remove the window frame assembly from the heater and
ensure that there is not hidden damage to the heater.
Take some time to plan the fitting line, flue and electrical supply.
On completion of the installation ensure that the appliance is
commissioned and tested.
Fitting Line Installation
Warning: When purging the fitting line, the front glass must be
removed.
Note: For pipe sizing requirements refer to Australian Standard AS5601
Gas Installations.
If gas fitting line has been previously completed, check that the gas fitting
line is of adequate size. Refer to Australian Standard AS5601 Gas
Installations.
The gas fitting line can be brought in through the rear or the bottom of the
appliance. Openings are provided on the bottom behind the valve to allow
for the gas fitting line installation and testing of any gas connection. It
preferable to bring the fitting line in from the rear right side of the valve as
this allows fan installation or removal without the need to disconnect the
gas fitting line.