Raypak HD101 Water Heater User Manual


 
44
hydrochloric acid/muriatic acid
cements and glues
antistatic fabric softeners used in clothes dryers
chloride-type bleaches, detergents, and cleaning
solvents found in household laundry rooms
adhesives used to fasten building products
... and other similar products.
Areas causing contaminated combustion air:
dry cleaning/laundry areas and establishments
metal fabrication plants
beauty shops
refrigeration repair shops
photo processing plants
auto body shops
plastic manufacturing plants
furniture refinishing areas and establishments
new building construction
remodeling areas.
Check for areas and products as listed above before
installing heater. If found:
remove products permanently, OR
provide outdoor combustion air.