Page 4
7036-135G
November 22, 2011
R
Mt. Vernon Pellet Insert (AE)
1
Listing and Code Approvals
A. Appliance Certifi cation
C. Glass Specifi cations
E. BTU & Effi ciency Specifi cations
This appliance is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
B. Mobile Home Approved
NOTE: This installation must conform with local codes. In
the absence of local codes you must comply with the ASTM
E1509-04, ULC S628-93, ULC/ORD-C-1482-M1990 and
(UM) 84-HUD.
D. Electrical Rating
115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps
*BTU output will vary, depending on the brand of fuel you
use in your appliance. Consult your Quadra-Fire dealer
for best results.
MODEL: Mt. Vernon Pellet Insert AE
LABORATORY: OMNI Test Laboratories, Inc
REPORT NO. 061-S-69-6
TYPE: Solid Fuel Room Heater/Pellet Type
Insert
STANDARD: ASTM E1509-04, ULC S628-93 and
ULC/ORD-C1482-M1990 Room Heater
Pellet Fuel Burning Type and (UM) 84-
HUD, Mobile Home Approved
FCC Complies with Part 15 of FCC Rules.
Operation is subject to the following
two conditions: (1) this device may not
cause harmful interference, and (2) this
device must accept any interference
received, including interference that
may cause undesired operation.
Emissions Rating: EPA Compliant
*BTU Output: 14,620 - 60,200 / hr
Effi ciency: 81.4% - 83.6%
Heating Capacity: 1,775 - 3,089 square feet depend-
ing on climate zone
Hopper Capacity: 56 lbs +/- 5 lbs
Fuel: Pellets, Shelled Field Corn, Wheat
and Black Sunfl ower Seeds
Shipping Weight: 425 lbs.
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is used.
The structural integrity of the mobile home fl oor, ceiling, and
walls must be maintained.
The appliance must be properly grounded to the frame of
the mobile home and use only Listed pellet vent Class “L”
or “PL” connector pipe.
A Quadra-Fire Outside Air Kit must be installed in a mobile
home installation. You must order the Outside Air Kit sepa-
rately.
NOTICE: Hearth & Home Technologies, manufacturer
of this appliance, reserves the right to alter its prod-
ucts, their specifi cations and/or price without notice.
Quadra-Fire is a registered trademark
of Hearth & Home Technologies.
WARNING! Risk of Fire! Hearth & Home Technologies dis-
claims any responsibility for, and the warranty and agency
listing will be voided by the above actions.
DO NOT:
• Install or operate damaged appliance
• Modify appliance
• Install other than as instructed by Hearth & Home
Technologies
• Operate the appliance without fully assembling all
components
• Overfi re
• Install any component not approved by Hearth &
Home Technologies
• Install parts or components not Listed or approved.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.
Note: The appliance is also approved for installation
into a shop.