Mt. Vernon Pellet Insert (AE)
1. Start-Up Cycle
During this cycle:
Igniter turns on for 90 seconds to heat up the air in the
repot
Combustion blower starts
Vacuum switch comes on
Feed motor turns on adding fuel to the fi repot and the
appliance waits for the fi re to start
The duration of start-up depends on the type and quality
of fuel used. It is normal to see some smoke during the
ignition process as moisture evaporates and the fuel lights.
The smoke will stop once the fi re starts.
K. Ignition Cycles
The appliance engine is controlled by the digital thermostat
wall control. The digital display on the wall control will tell
you what your appliance is doing in the upper left corner
(System Status). Figure 29.1.
READY
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
System Status
Every time the thermostat calls for heat, the appliance steps
through fi ve cycles:
1 Start-Up Cycle 4 Shutdown Cycle
2 Soft-Start Cycle 5 Auto-Clean Cycle
3 Heating Cycle
The duration and characteristics of these cycles may be dif-
ferent with each type of fuel selected.
Figure 29.1
WARNING! RISK OF FIRE!
Do NOT operate appliance:
With appliance door open
With fi repot fl oor open
With ash pan removed
2. Soft Start Cycle (SS-Low / SS-Med)
Once the fi re is lit:
The appliance moves into the low soft-start cycle as it
continues to build the fi re
More fuel will be added
As the fi re builds, the appliance will change to medium
soft-start mode
The heating cycle begins
3. Heating Cycle ( Auto / Man - L, ML, M, MH, H)
There are two choices in the Automatic / Manual menu of
how your appliance will operate:
Automatic Mode
The wall control will turn the heat output level up or down
depending on how far the room temperature is from the
desired temperature
The digital display will read AUTO:M, i.e. automatic-me-
dium level
As the room temperature approaches the desired tem-
perature, the appliance will turn down to lower settings
When the home reaches your set temperature, the appli-
ance will go into the shutdown cycle
Manual Mode
Set the heat output setting from the main screen
The right bottom button will read HEAT OUTPUT
You can operate the appliance from any of the 5 levels
On the lowest level (MAN: L) the appliance will stay on
longer, burn less fuel per hour, and will take longer to
bring the home up to your desired temperature
On the highest setting (MAN:H) the appliance will burn
more fuel per hour, and bring your home up to tempera-
ture more quickly
In Manual mode the heat output does not change but
will stay at the setting you chose until the comfort level
is reached (meaning the thermostat has been satisfi ed).
Turn to OFF to stop operation.
4. Shutdown Cycle
Once your home has reached your set temperature:
Appliance will stop feeding fuel and allow the fi re to dimin-
ish
Convection blower will continue to run until the appliance
cools to appropriate temperature
Appliance will begin the auto-clean cycle